Regulatory-aligned MIC testing and AMR interpretation for microbial safety assessment
Minimum inhibitory concentration (MIC) testing assesses the susceptibility of microbial production strains to clinically relevant antimicrobials. BaseClear uses standardized methods to identify resistance and support regulatory safety assessments.
This service supports microbial products such as food enzymes, feed additives, probiotics, and novel foods. It is especially relevant for EFSA and other regulatory submissions that require phenotypic AMR data alongside genomic analysis.
MIC testing uses standardized broth microdilution methods in line with CLSI guidelines. Antimicrobials are selected based on EFSA FEEDAP recommendations, with quality control strains included to verify assay validity. Results are interpreted against established cut-off values.
Clients receive a comprehensive, regulatory-ready report including MIC values, quality control results, and detailed interpretation aligned with EFSA expectations. Integrated with WGS analysis, the report enables clear differentiation between intrinsic and acquired resistance and provides justified interpretation of any deviations from reference ranges. All data are formatted for direct inclusion in regulatory dossiers, minimizing the need for further clarification.
From strain to regulatory-ready MIC data
We assess whether the strain grows under standard MIC conditions. Where necessary, conditions are adapted to ensure reliable and reproducible testing.
We define the antimicrobial panel and testing strategy based on regulatory requirements and strain type.
Your strain is tested using standardized broth microdilution assays under controlled laboratory conditions.
Quality control strains and acceptance criteria are applied to ensure data reliability and compliance.
Results are interpreted in line with EFSA guidance, including assessment of intrinsic versus acquired resistance.
Schedule a free consultation with our experts to discuss your testing needs and regulatory
requirements. We’ll help design a compliant testing workflow for your project.
MIC testing performed according to CLSI standards
Integrated wet-lab and bioinformatics workflows
Expertise in distinguishing intrinsic versus acquired resistance
Clear, dossier-ready reporting to support regulatory submissions
Minimum inhibitory concentration (MIC) testing determines the lowest concentration of an antimicrobial that inhibits visible growth of a microorganism. It is required to assess whether a production strain exhibits resistance to clinically relevant antimicrobials, which is a key safety concern in regulatory evaluations.
MIC testing is typically performed according to CLSI standards such as M07 and M45. These standardized methods ensure reproducibility and comparability of results and are accepted by regulatory authorities.
MIC results are interpreted by comparing measured values to established cut-off thresholds, such as EFSA cut-offs. Values above the cut-off may indicate acquired antimicrobial resistance and require further investigation and justification.
Intrinsic resistance is a natural, species-specific characteristic, while acquired resistance results from genetic changes such as mutations or horizontal gene transfer. Regulatory concern focuses on acquired resistance, as it may be transferable and pose a risk to human or animal health.
A one two-fold dilution difference from reference values is generally considered within acceptable experimental variation. However, results exceeding regulatory cut-offs must be carefully evaluated, including consideration of method performance, strain variability, and supporting genomic data.
MIC testing alone is not sufficient to fully assess antimicrobial resistance risk. A comprehensive evaluation requires integration of phenotypic MIC results with genomic analysis, including identification of resistance genes and assessment of their relevance.
Get expert guidance on MIC testing, interpretation, and regulatory strategy to avoid delays in your submission.
Start with a free consultation tailored to your project.
We use cookies to improve your experience on our site. By using our site, you consent to cookies.
Manage your cookie preferences below:
Essential cookies enable basic functions and are necessary for the proper function of the website.
These cookies are needed for adding comments on this website.
Google Tag Manager simplifies the management of marketing tags on your website without code changes.
Service URL: business.safety.google (opens in a new window)
These cookies are used for managing login functionality on this website.
You can find more information in our Cookie statement and Cookie statement.