Generate high-quality gene expression insights using Illumina-based RNA-Seq analysis, advanced bioinformatics pipelines, and differential expression analysis for bacterial and eukaryotic samples.
RNA-Seq analysis measures and compares gene expression across biological samples. BaseClear supports bacterial and eukaryotic samples for applications such as functional genomics, pathway analysis, host response studies, and biomarker discovery. Analyses are performed against a customer-provided reference genome.
This service supports biotechnology, pharmaceutical, food, industrial microbiology, and research organizations studying gene expression. Typical applications include treatment comparisons, fermentation studies, host-pathogen interactions, mechanism-of-action research, and differential gene expression analysis.
BaseClear combines high-quality Illumina sequencing with validated library preparation workflows and a state-of-the-art bioinformatics pipeline. Following sequencing, reads are aligned to the supplied reference genome and analyzed using updated RNA-Seq workflows to generate gene expression profiles and differential expression results.
Raw FASTQ files and aligned BAM files
Gene expression tables with raw counts and TPM values
Differential expression results with PCA, MA, and volcano plots
Methods, quality reporting, and expert support
From RNA Samples to Gene Expression Insights
Together, we define your research goals, sample type, reference genome, and study design, including sample groups for differential expression studies.
You send cells or purified RNA with the required project information. We perform RNA quality control and keep you updated throughout the study.
Samples undergo stranded RNA-Seq library preparation and Illumina NextSeq sequencing, with depth tailored to the application.
BaseClear aligns reads to the reference genome and quantifies gene expression. Differential analysis identifies significantly up- or downregulated genes.
You receive quality-filtered sequencing data, gene expression tables, alignment files, and an analysis report. Differential expression projects can also include PCA, MA, and volcano plots.
Schedule a free consultation with our experts to discuss your testing needs and regulatory
requirements. We’ll help design a compliant testing workflow for your project.
An annotated reference genome is required for BaseClear’s standard RNA-Seq analysis workflow. Customers must provide the species name and either an NCBI accession number or an annotated GenBank file to enable accurate read alignment and gene quantification. Because this service is designed for gene expression profiling rather than transcript discovery, de novo transcriptome assembly is not included in the standard analysis.
BaseClear uses organism-specific library preparation workflows to maximize transcriptome coverage and data quality. Bacterial samples are processed using rRNA depletion with Illumina Stranded Total RNA Prep and Ribo-Zero Plus, while eukaryotic samples undergo stranded polyA-selected mRNA enrichment. This tailored approach ensures that sequencing capacity is focused on biologically relevant transcripts while minimizing non-informative RNA species.
The recommended sequencing depth depends on the organism and study objectives. For bacterial samples, approximately 5 million reads per sample are typically sufficient for gene expression profiling, whereas eukaryotic samples generally require 10–30 million reads per sample. Higher sequencing depths can be selected for complex transcriptomes, low-abundance transcripts, or projects requiring increased statistical power.
Differential gene expression analysis includes both quantitative results and publication-ready visualizations. Clients receive tables containing fold changes, statistical significance values, and differential expression results, together with PCA plots, MA plots, and volcano plots that facilitate interpretation of transcriptional differences between experimental groups or conditions.
All RNA samples undergo quality control assessment before library preparation to verify RNA quantity and integrity. BaseClear recommends high-quality RNA with RIN values above 7.0 for bacterial samples and above 8.0 for eukaryotic samples, together with sufficient concentration and purity. If samples fail quality control, customers are informed promptly and alternative options are discussed before proceeding with the project.
We use cookies to improve your experience on our site. By using our site, you consent to cookies.
Manage your cookie preferences below:
Essential cookies enable basic functions and are necessary for the proper function of the website.
These cookies are needed for adding comments on this website.
Google Tag Manager simplifies the management of marketing tags on your website without code changes.
Service URL: business.safety.google (opens in a new window)
These cookies are used for managing login functionality on this website.
You can find more information in our Cookie statement and Cookie statement.